Troubleshooting 40

See the server LEDs and their status.

Item

Indicators

Status

Description

1

NIC LED

Blinking green

Ongoing activity

2

HDD LED

Blinking green

Ongoing activity

3

Power button

Amber/Green

Standby mode/Power on mode

4

Health LED

Amber/Blue/Red

Non-critical issue/Ongoing activity/Critical

issue

5

Network port

Blinking green

Ongoing network activity

6

Network port

Green

10/100/1000M connection

Health LED Behavior:

Critical issues

o

CPU initial failed

o

Memory initial failed

o

Fan failure or missing

o

Memory uncorrectable ECC

Non-critical issues

o

Voltage fault

o

Temperature fault

Preparing the server for diagnosis

1.

Be sure the server is in the proper operating environment with adequate power, air conditioning, and
humidity control. Refer to the server documentation for required environmental conditions.

2.

Record any error messages displayed by the system.

3.

Remove all diskettes and CDs from the media drives.

4.

Power down the server and peripheral devices if you will be diagnosing the server offline. Always
perform an orderly shutdown, if possible. This means you must: