HP ProLiant DL388e Gen8 Server User Manual

Page 54

Advertising
background image

Hardware options installation 54

Configuration

Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6

One processor,

nonredundant

Blank

Fan

Blank

Fan

Fan

Fan

One processor, redundant

Fan

Fan

Blank

Fan

Fan

Fan

Two processor, nonredundant Fan

Fan

Fan

Fan

Fan

Blank

Two processor, redundant

Fan

Fan

Fan

Fan

Fan

Fan

In a redundant fan mode:

o

If one fan fails, the system continues to operate without redundancy. This condition is indicated by
a flashing amber Health LED.

o

If two fans fail, the system shuts down.

The minimum fan requirement to make this server bootable is four fans in bays 2, 4, 5, and 6.

Installing a hot-plug fan module if the server is installed in a

ball-bearing rail system with the cable management arm

CAUTION:

To prevent the potential for thermal damage and system shutdown, ensure that a

functioning server has all feature bays populated with the required component or blank and the

access panel is installed within 60 seconds of being serviced.

1.

Pull down the quick release levers on each side of the server.

WARNING:

To reduce the risk of personal injury or equipment damage, be sure that the rack is

adequately stabilized before extending a component from the rack.

2.

Extend the server on the rack rails until the server rail-release latches engage.
If the server does not extend from the rack, use a T-25 Torx screwdriver to loosen the screws located
within the lever housing.

3.

Open the latch, slide the access panel to the rear of the chassis, and then remove the access panel.
If the latch is locked, use a T-15 Torx screwdriver to unlock the latch.

4.

Do one of the following: