Preventing unnecessary failover, Sharing volumes with other hp software products – HP XP Racks User Manual

Page 17

Advertising
background image

It is possible that maintenance operations require both storage systems to be powered off at the
same time. In this case, the health checking periods would be shortened to prevent unexpected
failover while both systems are powered off.

After failover, when a failure is corrected, you may continue operations on the S-VOL, though HP
recommends switching them back to the P-VOL. To find which volume was originally a P-VOL, use
the multipath software on the host to refer to path information, checking for the volume with the
owner path. The owner path is set to the volume that you specified as a P-VOL when you created
an ESAM pair. The owner path never switches even if the P-VOL and S-VOL were swapped due
to a failover.

Preventing unnecessary failover

Some applications issue the read command to the ESAM S-VOL. When these applications are
used, and when the number of read commands to the S-VOL reaches or exceeds the threshold
(1,000 times per six minutes), ESAM assumes that a P-VOL failure has occurred. This situation
results in an unnecessary failover to the ESAM S-VOL.

At this time, the Solaris VERITAS Volume Manager (VxVM) vxdisksetup command issues more
read commands than allowed by the threshold.

You can prevent unnecessary failover by setting host mode option 48 to ON. Note that when this
option is ON, the S-VOL responds slower to the read command.

Review system conditions and resulting behaviors related to host mode option 48 in the following
table.

Table 1 System behavior for host mode option 48

Behavior when ON

Behavior when OFF

Event

No failover, even when you run the
applications.

Failover occurs only when you run certain
applications.

Normal operation.

The S-VOL receives more
read commands than

Updates from a host go to P-VOL, and
S-VOL status remains PAIR.

Updates from a host go to S-VOL, and
S-VOL status becomes SSWS.

allowed by the threshold,

The S-VOL responds to the read
command as quickly as the P-VOL
responds.

The S-VOL responds slower to the read
command than the P-VOL does. The
S-VOL takes several milliseconds to
respond.

and receives no write
command.

Same as when option 48 is OFF.

The S-VOL receives one or
more write commands.

Updates from a host go to S-VOL, and
S-VOL status becomes SSWS.

The S-VOL responds to the read
command as quickly as the P-VOL
responds.

For more information about setting host mode options, see the HP XP P9000 Provisioning for Open
Systems User Guide
.

Sharing volumes with other HP software products

ESAM volumes can be used as volumes for other HP software products, such as Business Copy or
Virtual LUN.

The following table shows the ESAM volumes that can be shared with other software. Only those
volumes listed can be shared.

Preventing unnecessary failover

17