Installation instructions, Important, 1 install framing for hood support – GE PV970NSS User Manual

Page 14: Ductwork, wiring locations

Advertising
background image

14

49-80549-2

1 INSTALL FRAMING FOR HOOD

SUPPORT

IMPORTANT

³

Framing must be capable of

supporting 100 lbs.

If drywall is present, mark the screw hole locations

for the top mounting brackets. Remove the

template.
‡&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDO

studs at the bracket location indicated on the

template.

‡,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVWµ[µ

between two wall studs at the mounting screw

location. The horizontal support must be flush

with the room side of the studs. Use cleats behind

both sides of the support to secure to wall studs.

NOTE: 2 horizontal supports will be needed if there

is a stud located between the horizontal screw

locations (see figure).
IMPORTANT: Reinstall drywall for an even mounting

surface.

Installation Instructions

Centerline of

installation

space

View from rear

cleats

µ[µPLQ

mounting

support

DUCTWORK, WIRING LOCATIONS

'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG

• Locate the template packed with the literature.

–Measure 36” from the floor to the top of the

cooking surface. Add hood installation height

determined on pages 8 and 13. Mark that location.

–Use a level to draw a straight pencil line on the wall.

–Tape the template in position along the penciled

line. CHECK TO BE SURE THE TEMPLATE IS LEVEL.

Ceiling ducting:
,IGXFWZRUNZLOOYHQWVWUDLJKWXSWRWKHFHLOLQJ

• Use a level to draw a line straight up, from the

centerline on the template to the ceiling.

• Measure 5” from the back wall to the centerline of

DQµKROHRQWKHFHLOLQJ

NOTE: If drywall is not present, add drywall thickness

to the 5” dimension.

Wall Ducting:
,IGXFWZRUNZLOOYHQWWRWKHUHDU

• Use a level to draw a line straight up from the

centerline on the template.

‡0HDVXUHDWOHDVWµDERYHWKHSHQFLOOLQHWKDW

indicates the bottom installation height, to the
FHQWHUOLQHRIDQµGLDGXFWKROH +ROHPD\EH

elongated for duct elbow.)

HOUSE WIRING LOCATION:

‡7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI

the hood.

• Wiring should enter the back wall at least 18”

above the bottom of the hood and within 5” of the

left side of the centerline.

,167$//$7,21³9(17('727+(2876,'(

µPLQRSHQLQJIRUGXFWZRUN

REAR WALL

MOUNTING TEMPLATE

V

e

rt

ical

Centerline

ALIGN BOTTOM EDGE

WITH PENCIL LINE

INDICATING BOTTOM

OF THE HOOD

11-7/16"

Installation Height

Horizontal Line

CL

DRILL 2 (TWO) 3/16" PILOT HOLES THROUGH STUDS OR REAR WALL SUPPORT

10-1/8"

12-08 JR

2"

DRILL 2 (TWO) 3/16" PILOT HOLES THROUGH STUDS OR REAR WALL SUPPORT

12-1/2"

WALL VENT IS 27-3/4" MIN.

ABOVE THE INSTALLATION

HEIGHT

31-14772 Printed in Mexico

Ceiling

House Wiring

Location

CL

5”

18”

Min.

Wall vent

µ

min. above

installation

height

5” c enterline

to wall

Advertising
This manual is related to the following products: