Installation instructions, Warning, 6 connect electrical – GE PV970NSS User Manual

Page 21: 7 install duct covers

Advertising
background image

49-80549-2

21

Installation Instructions

6 CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not 2-wire

with a ground wire, a ground must be provided by the

installer. When house wiring is aluminum, be sure to
XVH8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQG

aluminum-to-copper connectors.

‡5HPRYHWKHVFUHZVRQWKHMXQFWLRQER[FRYHUDQG

the knockout on the top left side.

‡6HFXUHWKHKRXVHZLULQJWRWKHMXQFWLRQER[ZLWKD

strain relief.

• Connect the white lead to the branch circuit white

lead.

• Connect the black lead to the branch circuit black

lead.

‡&RQQHFWWKHJUHHQ\HOORZOHDGWRWKHEUDQFKFLUFXLW

green lead or bare ground lead.

• Secure all the connections with wire nuts on each

electrical connector.

‡3XVKWKHZLUHVLQWRWKHMXQFWLRQER[DQGUHSODFHWKH

cover. Be sure the wires are not pinched.

• Secure the MXQFWLRQER[FRYHUZLWKthe 6 original

screws.

Junction

ER[FRYHU

Knockout

7 INSTALL DUCT COVERS

• Remove protective plastic

covering.

• Assemble duct covers

according to application.

NOTE: The upper duct cover

has vent holes on one end

intended for use when the hood

is installed for recirculating

purposes. Be sure the vented
HQGLVDWWKHWRSWKHYHQWKROHV

will be visible in this installation.
Slide the upper duct cover into

the folded ends of the lower duct cover.

• Place the decorative duct covers on top of the hood.

‡([WHQGWKHLQQHUGXFWFRYHUXSZDUGWRWKHFHLOLQJ

bracket.

• Secure with 2 screws to the duct cover bracket.

Remove the packing material from the filter opening.

• Locate the screw holes on the inside front edge of

the opening. Install 2 screws to secure the lower

duct cover to the hood.

Mounting screws

Vent holes

Screw holes

Lower duct

cover seat

Duct cover

support

bracket

Lower

duct cover

Upper duct

cover

Duct cover

attachment tabs

Advertising