Installation Instructions

14

ADJUST BLOWER MOTOR

A3

Remove the screws holding the blower unit and

the screws securing the blower plate. Remove

the blower plate from the outer case by sliding it

toward the back of the microwave and pulling up.

1

Blower Plate

Blower Motor Screws

Blower

Motor

Screw

2 Carefully pull out the blower unit. The wires will

extend far enough to allow you to adjust the

blower unit.

$'-867%/2:(502725 FRQW

A3

Roll the blower so that fan blade openings are

facing the top of the oven. Place the blower back

into the opening.

Slide the blower plate back onto the microwave

by placing the side tabs into the slots and pushing

gently until the back tab is seated into the rear slot.

Replace 3 screws.

Note: Make sure the wires remain routed through the

openings in the motor frame. To avoid damage to

the fan motor wiring, insert motor carefully such that

the fan motor wiring does not contact the microwave

power cord bracket.

3

4

Back of
Mircrowave

Rotate 90°

WARNING:

5LVNRI(OHFWULF6KRFN

Can cause injury or death. Do not pull or stretch the
EORZHUXQLWZLULQJ0DNHVXUHWKHZLUHVDUHQRW

pinched.

Side Tab

Side Slot

Rear Slot

Rear Tab

Back of

Mircrowave

Fan Blades