Installation instructions, Caution, Adapting blower for outside back exhaust c4 – GE JVM3160DFWW User Manual

Page 22: Attach the mounting plate to the wall cont c2

Advertising
background image

2

1 Remove the blower motor screws that holds the blower

plate to the microwave oven. Slide the plate toward the

back of the microwave and lift up to remove.

ADAPTING BLOWER FOR

OUTSIDE BACK EXHAUST

C4

Remove screw on the back of the unit.

22

USE TOP CABINET TEMPLATE

FOR PREPARATION OF TOP

CABINET

C3

‡ Read the instructions on the TOP CABINET

TEMPLATE.

‡ Tape it underneath the top cabinet.
‡ Drill the holes, following the instructions on the

TOP CABINET TEMPLATE.

CAUTION:

:HDUVDIHW\JRJJOHVZKHQ

GULOOLQJKROHVLQWKHFDELQHWERWWRP

Wall

Mounting

Plate

Spacing for Toggles More

Than Wall Thickness

Toggle

Bolt

Toggle Wings

7RXVHWRJJOHEROWV

Bolt

End

Installation Instructions

You need to drill holes for the top support screws and

a hole large enough for the power cord to fit through.

Place the mounting plate against the wall and insert

the toggle wings into the holes in the wall to mount

the plate.

NOTE: Before tightening toggle bolts and wood screw,

make sure the tabs on the mounting plate touch

the bottom of the cabinet when pushed flush against

the wall and that the plate is properly centered under

the cabinet.

CAUTION:

%HFDUHIXOWRDYRLGSLQFKLQJ

ILQJHUVEHWZHHQWKHEDFNRIWKHPRXQWLQJSODWHDQG

the wall.

Tighten all bolts. Pull the plate away from the wall

to help tighten the bolts.

3

4

Blower Plate

Blower Motor Screws

The fan needs to be turned 180 degrees to the right

to be in the correct orientation, keeping the blower

part of the fan where the air comes out at the top

of the fan. The wire needs to be reinsterted into the

cage housing once it has been oriented correctly.

4

Back of Microwave

Fan Blades

Wires

3

ATTACH THE MOUNTING PLATE

TO THE WALL cont

C2

Screw

Carefully remove fan from cavity. Remove the wire

from the notch at the bottom of the fan after it is

removed from the cavity.

5

Remove the knockout plates in the back of the unit

with snips.

Back of mircrowave

Knockout Plates:

Snip all 4 webs on

each knockout panel

and remove the metal

knockouts for rear airflow.

Please take care to

remove any sharp edges

created from removing

the knockout plates.