Island installation preparation, Construct ceiling support – GE ZVC42LSS User Manual
Page 14
 
14
Plan the Location of the Hood and Ductwork
The ceiling structure must be capable of supporting the 
weight of the insert sleeve (approximately 100 pounds), 
the canopy itself, any mounting hardware and any 
inadvertent user contact loads. 
• Use a plumb bob to check the location. 
Thecountertop/cooktop below the insert sleeve must 
be centered with the insert sleeve.
• If desired, install the control in a remote location
using the supplied mounting hardware. See the 
following pages for detailed instructions for 
mounting the control remotely.
• Refer to Ceiling Ducting on page 13 for ductwork
installation.
IMPORTANT: The exhaust outlet in the top of the
insert sleeve is not centered; it is positioned closer 
to the back side. Therefore, the insert sleeve may 
not be centered front to back in the canopy. A 
custom liner constructed by the cabinet supplier 
is usually required for island installations.
NOTE: It is recommended that the custom hood
insert be purchased and on-site before the canopy 
is constructed. 
CONSTRUCT CEILING SUPPORT
(for Island Installation)
Island Installation Preparation
Ceiling
Hood
ducting
centerline
Countertop
Front
Front view
Align with
center of
cooktop
*30" Minimum required
*36" Maximum
recommended
installation height
Cooktop
* Always refer to the cooktop or range installation
instructions for product-specific clearances.
• The insert sleeve in the canopy must be centered
left to right over the cooktop.
Left side view
*30" Minimum required
*36" Maximum recommended
installation height
Illustrations not to scale