Installation Instructions

STEP 2 CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not

2-wire with a ground wire, an electrician will need

to convert existing wiring to meet these specs.

When house wiring is aluminum, be sure to use

U.L.-approved anti-oxidant compound and

aluminum-to-copper connectors.

1. Place insert sleeve on padded, yet stable, surface

below cutout (can use flattened carton to pad

surface).

2. Remove the junction box cover.

3. Pull house wires through wall of insert sleeve and

attach the strain relief. Thread the house wire

through the junction box.

4. Connect white leads to branch circuit white lead.
5. Connect black leads to branch circuit black lead.
6. Connect green/yellow leads to branch circuit green

lead.

7. Secure all connections with wire nuts.

8. Carefully push wires into junction box and replace

cover.

9. Secure junction box cover with original screws.