Design information, Product dimensions – GE ZVC42LSS User Manual
Page 6
 
6
Design Information
PRODUCT DIMENSIONS
27-1/2"
14"
16-3/4"
25-3/4"
13"
14"
4"
34-1/2"
21-1/4"
1/2"
4-1/4"
7-1/2"
The bottom edge of the insert sleeve has a 7/8"
wide flange on the sides and a 1/2" wide flange on
the front and back.
Remote Location for the Control
The control may be removed from the hood 
and installed into a wall or countertop. A 30-ft. 
length of wire is supplied to accommodate most 
installations. A blanking plate covers the opening 
when the controls are removed.
The overall size of the control is 4-1/4" wide and 
2-1/4" deep.
We recommend that the cutout in granite or other 
hard surfaces be made before the countertop is 
installed.
7/8"
1/2"
1/2"
The stainless steel liner is shipped with each hood 
insert. This non-combustible liner protects the 
underside of the canopy.
Custom Liner
If you are not using the supplied liner, you may 
construct a custom non-combustible liner. Use the 
supplied liner as a template. The opening must 
be 26"W x 13-3/16"D. 3/4"thick material must 
surround the opening to allow the sleeve locking 
clips to engage. The insert sleeve inside the cabinet 
should be positioned 1/2" from the rear wall so 
that the center of the 8" duct is 5-1/2" from the 
rear wall.
*Opening
ZVC36
The custom canopy must be sized to fit the insert
sleeve. Construct the canopy with an opening
that is:
26"W x 13-3/16"D
The opening must be constructed of 3/4" thick 
material to allow the sleeve locking clips to 
engage.
The Supplied Liner
Dimensions and Specifications (in inches)
Outside Dimensions
The Insert Sleeve
13"
1-11/16"
3-11/16"
Control cutout
Front side
Front side