GE ZVC42LSS User Manual

Page 4

Advertising
background image

4

Design Information

CONTENTS

Design Information

Product Clearances .......................................................................... 4

Product Dimensions .................................................................... 5–8
Advance Planning

Advance Planning ............................................................................ 9

Remote Mounting of the Control (Wired) ............................. 9

Power Supply ..................................................................................... 9

Duct Fittings ................................................................................... 10
Installation Preparation

Tools and Materials Required ....................................................11

Remove the Packaging ...............................................................11

Parts Provided .................................................................................12

Ductwork, Wiring Locations .......................................................13

Construct Ceiling Support ...........................................................14

Remote Mounting of the Control – Wired .................... 15, 16

Installation Instructions
Step 1, Install Hood Liner .............................................................17

Step 2, Connect Electrical ............................................................18

Step 3, Install Insert Sleeve .........................................................19

Step 4, Install Damper Plate .......................................................20

Step 5, Install Blower Motor .......................................................21

Step 6, Connect Wiring Harness ..............................................21

Step 7, Install Filters .......................................................................22

Step 8, Finalize Installation .........................................................22

PRODUCT CLEARANCES

The vent hood and liner assembly must be installed

30" minimum and 36" maximum above the cooking

surface.
• Always refer to the cooktop or range installation

instructions for product-specific clearances.

NOTE: Installation height should be measured from

the cooking surface to the bottom edge of the metal

hood liner or cabinet surface.
NOTE: UL requires any combustible surface to be a

minimum of 30d above the cooking surface.
• This hood must be vented to the outdoors.
• This hood may be mounted onto a wall or installed

over an island.

• This hood can be installed over any Monogram

electric/gas cooktop or Monogram Professional
cooktop or range of equivalent width.

*30"Minimum required

*36"Maximum recommended

36"min.

* NOTE: Rear wall exhaust venting may affect

installation height. See page 13.