GE 58420 GE Automatic Light-Sensing Timer User Manual

Light-sensing timer, Warning, Automatic light controller

Advertising
background image

Rating: 120 VAC
150 W Max Incandescent
- Maximum wattage depends on your application.

See Figure 1 for proper maximum wattage bulb to use.
ENCLOSED YOU WILL FIND

• Light-Sensing Timer
OPERATING DESCRIPTION:

Your Light-Sensing Timer is activated by changes in

surrounding light. For optimum performance, the

Light-Sensing Timer should be positioned in an area

exposed to a strong source of natural light. For indoor

applications, ideal positioning is in a lamp fixture located within 4 ft. of a

window or other light source.
Once power is supplied to your Light-Sensing Timer, the control will turn on

at dusk (or when the surrounding light level becomes low enough) and then

turn off after the selected time period. Once the bulb automatically turns off,

it will remain off until the following night. At dusk on the following night, the

Light-Sensing Timer will once again turn on, then turn off after the user

selected time period. As long as power is supplied to the control, the

Light-Sensing Timer will continue to cycle on and off in this manner.
INSTALLATION (For use indoors or in enclosed fixtures)

1. Turn "OFF" power to light fixture.

2. Screw Light-Sensing Timer into light fixture.

3. Screw bulb into Light-Sensing Timer.

4. Position control so that the photocell eye faces a strong source of light.

5. Turn "ON" power to light fixture (middle setting for 3-way lamp).

Light-Sensing

Timer will begin to operate in 30 to 60 seconds.

1

3

2

OPERATING INSTRUCTIONS

• Your Light-Sensing Timer has two adjustment features

a) Timing Adjustment - Adjust “Timer” knob as desired to a minimum

setting of approximately one hour to a maximum of approximately six

hours.

b) Sensitivity Adjustment - Adjust “Turn-On” knob to left

(counterclockwise)

for earlier (brighter) activation or right (clockwise) for later (darker)

activation.
• Once the timing cycle begins, the lamp will remain on for one cycle

duration

regardless of light level.
• To force on or extend the timing

cycle for additional one to six hours.

a) In dark conditions, turn off lamp for

approximately 60 seconds, then

turn on. After 15 seconds, light

bulb

will turn on and timing cycle will

begin.

b) In light conditions, completely

cover

photocell eye until

light bulb turns on.

ADJUSTMENTS

• After measuring the length of one

timing cycle, adjust knob according

to preference. Setting the “Timer”

knob to mid-range, will result in a

2

1

/

2-

to 3

1

/

2-

hour timing cycle.

• To adjust the light sensitivity setting, set “Turn-On” knob to center

position.

If lamp turns on before the desired darkness level is reached (i.e. early

dusk),

adjust knob clockwise. If lamp turns on after the desired darkness level is

reached, adjust knob counterclockwise.

Note:

The Light-Sensing Timer requires a certain amount of surrounding

light during the day to reset. Some applications may require initial knob

adjustments to ensure re-set conditions are met so your Light-Sensing

Timer will operate properly. See troubleshooting section for details.

TROUBLESHOOTING

Problem:

Control turns on at dusk during the first night of operation but

does not turn on at dusk during the second night (or second timing cycle)

of operation. This means the Light-Sensing Timer did not see enough light

during the daylight hours to reset. This problem usually occurs on cloudy

or overcast days when there is no sunlight.

Solution:

Move Light-Sensing Timer closer to a natural light source

and/or adjust the “Turn-On” knob clockwise. Repeat on subsequent nights

if necessary.

Problem: Light-Sensing Timer

does not turn on at all.

Solution:

Make sure power is supplied to light fixture. Ensure light bulb is

not burned out. For 3-way lamp fixtures, make sure the lamp switch is set

at the middle switch position. The Light-Sensing Timer should turn on after

photocell eye sees darkness or after photocell eye is completely covered.

Light

Sensor

Knob

Timer

Knob

Sensor

LAMP

150 Watt Max

OVERHEAD LAMP

100 Watt Max

UPRIGHT COACH LAMP

60 Watt Max

PENDANT COACH LAMP

40 Watt Max

Figure 1

WARNING

Risk of electric shock

• Turn power off before inspection, installation or

removal

• Keep children away

• Use indoors or with enclosed fixtures only

• Do not use in wet locations
Risk of fire

• Do not exceed electrical ratings

• Do not use to control receptacle outlets, fluorescent

lighting fixtures, motor-operated appliances or

Light-Sensing Timer

Automatic Light Controller

INSTRUCTION MANUAL

is a trademark of the

General Electric Company

and is used under license to

Jasco Products Company LLC,

311 N.W. 122nd Street,

Oklahoma City, OK 73114.

www.jascoproducts.com

3.875"

3.25"

3.25"

3.875"

58420-3 IN rev. 6/6/06