GE 45610WB GE Z-Wave Add On Auxiliary Switch User Manual

Page 10

Advertising
background image

Z-Wave 45607, 45609 or 45612
1. Shut off power to the circuit at fuse box or circuit

breaker.

2. Remove wall plate.
! Warning: Verify power is OFF to switch box before

continuing.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO

NOT disconnect the wires.

5. There are five wiring connections on the Z-Wave

dimmer and switch; these are marked LINE (Hot),

NEUTRAL, LOAD, GROUND and TRAVELER. The

Traveler terminal is only used for 3-way, 4-way or

5-way wiring and should be insulated if the dimmer/

switch is being installed in a single pole, 2-way

system (one switch & one load). Match these leads

or screw terminals to the wires connected to the existing

switch.

6. Disconnect the wires from the existing switch.
7. Connect the green or bare copper ground wire to the

GROUND lead or terminal.

8. Connect the white wire to the lead or terminal marked

NEUTRAL. (The 45612 does not have a connection to

Neutral)

9. Connect the black wire that goes to the light to the lead

or terminal marked LOAD.

Advertising