INSTALLATION
This switch may be used in new installations or to replace
an existing wall switch when converting a 3 or 4 way circuit
to Z-Wave.
It can not be used by itself for 2-way control
(one switch & one load).
Please note: The Auxiliary switch(s) must be wired to
the same Neutral as the Z-Wave enabled switch and the
lighting device. It must not be wired to any other Neutral. If
multiple Neutrals are tied together in one box, separate the
neutrals to preserve the integrity of the circuit.
3-Way Wiring Schematic using one 45610 and one
45607, 45609 or 45612
White (Neutral)
Z-
Wave
45610
Z-Wave
45607,
45609 or
45612*
Black (Line / Hot)
Black
(Load)
Traveler - Colored (Not Green)
Green (Ground)
* The
45612
does not
have a
connection
to Neutral