Trouble shooting your hydraulic system – Ashland 1200 TR User Manual
Page 32

32
TROUBLE SHOOTING YOUR HYDRAULIC SYSTEM
PROBLEM
POSSIBLE CAUSES
REMEDY
Failure of pump to
Low fluid level in reservoir
Add recommended oil and
deliver fluid
check level to be certain pump
suction line inlet is submerged
deeply enough to prevent air
entering directly or by the
formation of a vortex.
Oil intake pipe or strainer
Clean or replace
plugged
Air leak in suction line, prevent
Repair leaks
priming or causing noise and
irregular action of control circuit
Oil viscosity too heavy to pick
Use lighter viscosity oil or
up prime (especially in cold
install a low density immersion
weather)
heater (with steel element only)
Wrong direction of rotation
Must be reversed to prevent
damage to pump
Broken pump shaft or parts
Replace
broken inside pump
Pump making a noise
Intake line, suction filter of pipe
Clean intake, filter or eliminate
restricted
restriction. Be sure suction
line is completely open
Air leaks
1) At pump intake piping joints
1) Tighten as required
2) At pump shaft packing (if
2) Repair or replace
present) or seals
3) Air drawn in through inlet
3) Be sure suction and return
pipe opening
lines are below oil level in
reservoir
Reservoir air vent plugged
Air must be allowed to breathe
in the reservoir. Clean or
replace reservoir breather .
Too high oil viscosity
Use lower viscosity oil. Check
recommendations in start-up
information
Coupling misalignment
Re-align
Worn or broken parts
Replace