2-26

2.11 USING THE IR ILLUMINATOR (Continued)

IR Illuminator Pulse Rate

In addition to momentary and continuous modes of

operation, the IR Illuminator may be programmed to operate

in pulse mode at either 1, 2, 4, or 8 pulses per second.

NOTE

To access the programming mode, the Mode

Selector must be turned to the desired pulse rate

within 5 seconds of pressing the FIRE Button.

1. With the Mode Selector turned to the P (PROGRAM)

position, hold down the FIRE Button.

2. Turn the Mode Selector to the IR position that

corresponds to the desired pulse rate as shown in Table

2-9. The LED Status Indicator will display a flashing

green light that corresponds to the pulse rate (e.g., four

green flashes indicate a pulse rate of four pulses per

second).

Table 2-9. IR Illuminator Pulse Rates.

Pulse Rate

Mode Selector Position

Program

P

Continuous (no pulse)

AL

1 pulse per second

DL

2 pulses per second

AH*

4 pulses per second

IH*

8 pulses per second

DH*

* The safety screw must be removed to program these pulse rates.

3. Release the FIRE Button, and the pulse rate will be

programmed. The set pulse rate will remain until it is

programmed differently.