3.3 CORRECTIVE MAINTENANCE (Continued)

7. Simultaneously stretch and pull the larger eye of the

battery cap lanyard over the battery cap threads. Work

the lanyard until it is seated neatly in the groove closest to

the ATPIAL housing.

8. Stretch the o-ring over the battery compartment threads

and slip it into its retaining groove (see Figure 3-1).

9. Reinstall the battery cap and tighten.

Replacing IR Illuminator Diffuser Lens Cap

1. If applicable, remove the old lens cap by pulling it off the

ATPIAL housing.

2. Stretch the looped end of the replacement lens cap

around the Illuminator Focus Ring.

3. Work the looped end down the Focus Ring toward the

ATPIAL housing, until it is seated neatly in its retaining

groove.

4. Flip the lens cap up and over the IR Illuminator.

Figure 3-3. Replacing IR Illuminator Diffuser Lens Cap.