AMX NetLinx Integrated Controllers NI-700/900 User Manual

Page 7

Advertising
background image

Introduction

3

NI-700 & NI-900 Hardware Reference Guide

NI-700 Specifications (Cont.)

Rear Panel Components (Cont.):

IR RX
(Port 5)

• 4-pin 3.5 mm mini-Phoenix port is used to connect one or more (8 maximum)

IRX-SM+ swivel mount or IRX-DM+ Decora mount IR receivers.

• The IR RX port functions using AMX IR codes (38 KHz and 455 KHz) and works

ONLY with AMX IR Receivers such as the IRX-DM+ and IRX-SM+.

Digital I/O
(Port 4)

• Four-channel binary I/O port for contact closure with each input being capable of

voltage sensing.

• Input format is software selectable.
• Interactive power sensing for IR ports
• Channel range = 1 - 4
• All inputs are assigned to respective IR/Serial ports for "automatic" power control

through the use of software commands. Power control is provided via
commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).

• Contact closure between GND and an I/O port is detected as a PUSH
• When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as a

PUSH and a high signal (3.5 - 5 VDC) as a RELEASE

• When used as an output - each I/O port acts as a switch to GND and is rated at

200 mA @ 12 VDC

• Single 6-pin 3.5 mm mini-Phoenix (female) connector provides I/O port

termination

Note: This IO uses 5V logic but can handle up to 12V without harm. It can handle
up to 12V on the input. At higher voltages you run a higher risk of surge damage.

IR/Serial
(Port 3)

• 4-pin 3.5 mm mini-Phoenix port is capable of generating IR with the use of an IR

Emitter (while in IR mode). This port can support high-frequency carriers of up
to 1.142 MHz and can also generate IR with no carrier frequency.

• The output is capable of three electrical formats: IR, Serial, and Data
• Single IR/Serial signal can be generated.
• Channel range = 1 - 255
• Channels 1 - 128 (output): IR commands
• Channels 129 - 253: used as reference channels
• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF' commands)
• Channel 255 (feedback): Power status (when IO Link is set)
• IR ports support data mode (at limited baud rates and wiring distances).
• Single 2-pin 3.5 mm mini-Phoenix (female) connector provides IR port

termination

AXlink LED

• Green LED indicates the state of the AXlink connector port.
• Normal AXlink activity = 1 blink/second
• Abnormal AXlink activity = cycle of 3 consecutive blinks and then Off

AXlink port

• 4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to external

control devices.

Ethernet port

• RJ-45 port for 10/100 Mbps communication. The Ethernet Port automatically

negotiates the connection speed (10 Mbps or 100 Mbps) and whether to use half
duplex or full duplex mode.

Ethernet Link/
Activity LED

• Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show

communication activity, connection status, speeds, and mode information:

SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps and
turns Off when the speed is 10 Mbps.
L/A (link/activity) - Green LED lights On when the Ethernet cables are connected
and terminated correctly, and blinks when receiving Ethernet data packets.

Power port

• 2-pin 3.5 mm mini-Phoenix (male) connector.
• Use a 12 VDC-compliant power supply to provide power to the NI-700 through

the 2-pin 3.5 mm mini-Phoenix connector on the rear panel.