Configuration and Installation

4

AXB-DTMF+ DTMF+ Interface

Line Setting mode

The 2-position jumper JP1 selects

PHONE

or

LEASED

line operation when system powers on.

FIG. 3 shows the default setting.

To change the line setting default from

PHONE

to

LEASED

:

1.

Remove the AXB-DTMF+ cover from the unit housing.

2.

Remove the jumper from pins 2 and 3, and place it on pins 1 and 2.

3.

Re-install the AXB-DTMF+ cover onto the unit housing.

Wiring the AXB-DTMF+

Preparing captive wires

To connect the wiring into a captive-wire connector:

1.

Strip 1/4 inch off the wire insulation for all four wires.

2.

Tin 2/3 of the exposed wire.

3.

Insert each wire into the appropriate captive-wire connector up to the insulation.

4.

Tighten the captive screws to secure the fit in the connector.

Wiring guidelines

The interface requires a 12 VDC power to operate properly. The interface uses a PSN2.8 power

suppl. The Central Controller supplies power via the AXlink cable or external 12 VDC power

supply. The maximum wiring distance between the Central Controller and interface is determined

by power consumption, supplied voltage, and the wire gauge used for the cable. The table below

lists wire sizes and maximum lengths allowable between the AXB-DTMF+ and Central Controller.

The maximum wiring lengths for using AXlink power are based on a minimum of 13.5 volts

available at the Central Controller’s power supply.

FIG. 3 Line Setting jumper JP1 (default setting = PHONE)

pin 3
pin 2
pin 1

Phone

Leased

If the device is using a separate power supply, do not connect the power wiring from
the AXB-DTMF+ to that device.

Wiring Guidelines at 80 mA

Wire Size

Maximum Wiring Length

18 AWG

1467.14 feet (447.18 m)

20 AWG

928.22 feet (282.92 m)

22 AWG

578.70 feet (176.39 m)

24 AWG

364.79 feet (111.19 m)