Installing the New Water Heater (cont’d)

MIN. RISE

1

8

PER FIVE FEET

MIN. RISE

1

8

PER FIVE FEET

MIN. RISE

1

8

PER FIVE FEET

3 ELBOW

EXAMPLE

16

″ MIN.

MIN. RISE

1

8

PER FIVE FEET

13

1

2

″ MIN.

12

″ MIN.

1. Horizontal runs require a minimum

1

8

″ rise per five feet.

40 AND 50 GALLON MODELS 50,000 BTU/HR AND

HIGHER, 75 GALLON MODELS (3

VENT)

VENTING SYSTEM EXAMPLE INSTALLATIONS FOR

ALL MODELS

The vent piping cannot under any circumstances be run

downhill.

The vent piping may be installed as follows:

3 ELBOW

EXAMPLE

MIN. RISE

1

8

PER FIVE FEET

MIN. RISE

1

8

PER FIVE FEET

3. A 3

″ PVC, ABS or CPVC Schedule 40 pipe, minimum

length of 3

″ (must be supplied locally), to make vent

connection at the blower outlet.

4. A 3

″ to 2″ PVC, ABS or CPVC Schedule 40 reducer

(must be supplied locally).

5. A 2

″ PVC, ABS or CPVC Schedule 40-90° street ell; used

to connect the vent pipe to the reducer when the vent

pipe is to be turned horizontally off the blower (supplied

locally).

6. 2

″ PVC, ABS or CPVC Schedule 40 pipe (must be sup-

plied locally).

7. The water heater requires its own (separate) venting

system.

8. 2

″ and 3″ PVC, ABS, or CPVC Schedule 40 piping and

fittings are acceptable materials for the vent system on

all 40 and 50 gallon 40,000 BTU/HR models.

9. It cannot be connected to existing vent piping or

chimney.

10. It must terminate horizontally to the outdoors.

NOTE: See pages 21 and 22 for vertical venting through a

roof.

3 ELBOW

EXAMPLE

SEE CHART ON PAGE 18 FOR MAX. LENGTH

2

″ PVC, ABS OR CPVC

SCHEDULE 40 90°

STREET ELBOW

2

″ PVC, ABS OR CPVC

SCHEDULE 40 PIPE

VENT CAP

AND SCREEN

3

″ PVC, ABS OR CPVC

SCHEDULE 40 PIPE

(MINIMUM LENGTH 3

″)

3

″ TO 2″ PVC, ABS OR

CPVC REDUCER