Gas Piping

22

Installing the New Water Heater (cont’d)

WARNING

Make sure the gas supplied is the same type listed on the

model rating plate. The inlet gas pressure must not exceed

10.5 in. water column (2.6kPa) for natural gas or 13 in.

water column (3.2kPa) for propane (L.P.) gas. The mini-

mum inlet gas pressure listed on the rating plate is for the

purpose of input adjustment.

WARNING

If the gas control valve is subjected to pressure exceeding

1

/

2

pound per square inch (3.5kPa), the damage to the gas con-

trol valve could result in a fire or explosion from leaking gas.

WARNING

If the main gas line shutoff serving all gas appliances is

used, also turn “OFF” the gas at each appliance. Leave all

gas appliances turned “OFF” until the water heater instal-

lation is complete.

POSITION FIRESTOP

SUPPORT LATERALS

MIN. EVERY 3

1

/

2

45° ELBOW

MAINTAIN LISTED

CLEARANCE

SEAL AROUND

FLASHING

VENT CAP MUST

BE POSITIONED

DOWNWARD

SCREEN

18

″ MIN.

EACH VENT

MAINTAIN LISTED

CLEARANCE

SUPPORT IF NECESSARY

MAINTAIN LISTED

CLEARANCE

EXHAUST VERTICAL

VENT

CERTIFIED

WATER HEATER

TOTAL VERTICAL

AND HORIZONTAL

RUNS - SEE ITEM 6.

45˚ VENT CAP

90˚ STREET

ELL

6. The total vertical and horizontal vent run cannot

exceed the maximum length with the number of 90˚

elbows as specified in the tables below and in the next

column. If more elbows are required the venting dis-

tance must be reduced 5 feet for every 90˚ elbow.

VENTING THROUGH A ROOF (cont’d)

ALL 40 and 50 GALLON 40,000 BTU/HR MODELS ONLY

3

″″ DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

115

1

110

2

105

3

100

4

95

5

90

6

ALL 40 and 50 GALLON 40,000 BTU/HR MODELS —

OPTIONAL 2

″″ VENT PIPING

2

″″ DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

50

1

45

2

40

3

35

4

30

5

25

6

*NOTE: Two 45° elbows are equivalent to one 90° elbow.

One 90° elbow equals 5 feet of equivalent vent length.

75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON

52,500, 55,000 and 62,500 BTU/HR and 40 GALLON

50,000 BTU/HR MODELS ONLY

3

″″ DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

70

1

65

2

60

3

55

4

50

5

45

6

75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500,

55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR

MODELS ONLY – OPTIONAL 4

VENT PIPING

4

″″ DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

110

1

105

2

100

3

95

4

90

5

85

6