33

PROBLEM

CHECK THIS

POSSIBLE CAUSE

CORRECTIVE ACTION

Not enough hot water (cont.)

Differential Controller

Improper wiring or loose
connections)

Compare with system
schematic. Check for proper
connections. Seal all splices
against moisture

Isolation valves

Closed

Open

Thermostatic mixing valve

Improper adjustment

Check water temperature at
house faucet and adjust valve
setting

Valve defective

Replace. System must not
be run without thermostatic
mixing valve due to scald risk.

Piping

Insuffi cient Insulation

Add insulation where required

High heat losses

Check insulation for splits,
deterioration, absence

Nighttime thermosyphoning

Check for pump operation at
night

Improperly plumbed

Compare with system
schematic. Check fl ow
direction

Flow blockage

Flush system. Check effl uent
for debris.

Low system pressure

Check pressure gauge. Set
system pressure to correct
setting, check for leaks.

Pump

No power

Check breaker, pump cord,
and controller fuse. Repair or
replace

Flow rated too high or too low

Adjust fl ow rate

Faulty pump

Listen for irregular noises
in pump operation. Feel
collector feed and return line
for temperature difference.
Ensure all air is purged from
system.

Runs continuously

Check sensors for shorts

No hot water in the morning

Storage water heater

Circuit breaker shut off

Turn breaker on

Differential controller

Sensor wires reversed

Ensure the collector and
tanks sensors are wired to
the correct position on the
controller

Water too hot

Thermostatic mixing valve

Improper adjustment

Check water temperature at
house faucet and adjust valve
setting

Valve defective

Replace. System must not
be run without thermostatic
mixing valve due to scald risk.

No water

Cold-water supply valve

Valve closed

Open valve

Pump does not start

Differential controller

Controller set to “off” position

Set system operation to
“Auto”

Unplugged

Return power to controller

On and/or off temperature
differential set points too high

Reset on and off
differentials according to
recommendations

Loose contacts

Clean contacts and tighten
connections or replace

Blown fuse

Replace fuse