State Deluxe Systems User Manual

Page 34

Advertising
background image

34

PROBLEM

CHECK THIS

POSSIBLE CAUSE

CORRECTIVE ACTION

Pump does not start

Electrical power supply

Controller plug disconnected

Reconnect control plug to
power outlet

Blown fuse or breaker tripped
on overload

Determine cause and replace
fuse or reset breaker

Pump

Motor failure

Replace pump

Sensors

Defective sensors, sensor
error

Check wiring continuity.
Repair or replace

Pump starts, but cycles
continuously

Differential controller

On and/or off temperature
differential set points too low

Reset on and off
differentials according to
recommendations

Piping

Reversed connections to
collectors

Compare with system
schematic and reconnect
properly

Sensors

Improper location

Compare with system
schematic and reconnect
properly

Pump cycles after dark

Differential controller

Recooling function active
and max temperature setting
exceeded

Controller operating properly.
No fault.

Sensors

Defective sensors, sensor
error

Check wiring continuity.
Repair or replace

Pump runs continuously

Differential controller

Off temperature differential set
too low

Reset off differential according
to recommendation

Controller set to “on” position

Set system operation to
“Auto”

Pump operated but no fl uid
fl ows from collectors

Air Scoop

System air-locked

Purge air from air scoop in
solar pump station by opening
valve slowly. Caution: after air
is evacuated fl uid will fl ow out
in a small stream and may be
hot. Cover port with a rag to
catch any fl uid.

Air vent

System air-locked

Open air vent on the top of the
system and purge excess air.
Close after purging.

Fluid

Loss of fl uid from system

Locate leak and repair

Isolation valves

Valves in closed position

Open valves

Piping

Clogged or damaged piping

Unblock piping or repair
damaged piping

Pump

Broken impeller shaft

Replace shaft

Not vented properly

Install in correct orientation

Undersized

System piping run too long.
Refer to maximum piping
lengths and adjust

Noisy system

Air vents

Air trapped in system

Open air vent and purge air
scoop in solar pump station
by opening the valve slowly.
Caution: after air is evacuated
fl uid will fl ow out in a small
stream and may be hot.
Cover port with a rag to catch
any fl uid.

Pump

Bearings are dry or have
excessive wear

Lubricate or replace

Impeller loose

Tighten or replace impeller