6.7 Module 7 - s

erIal

c

oMMunIcatIons

p

araMeters

(



)

PARAMETER MENU







DATA BIT





PARITY BIT




















BAUD RATE

Set the baud rate to match that of other serial communications equipment.

Normally, the baud rate is set to the highest value that all of the serial

communications equipment is capable of transmitting.

Select either 7 or 8 bit data word lengths. Set the word length to match that

of other serial communication equipment. Since the meter receives and

transmits 7-bit ASCII encoded data, 7 bit word length is sufficient to request

and receive data from the meter.

Set the parity bit to match that of the other serial communications equipment

used. The meter ignores the parity when receiving data, and sets the parity bit

for outgoing data. If no parity is selected with 7-bit word length the meter

transmits and receives data with 2 stop bits. (For example: 10 bit frame with

mark parity)









ABBREVIATED PRINTING

PRINT OPTIONS



METER ADDRESS

to











Enter the serial node address. With a single unit on a bus, an address is not

needed and a value of zero can be used (RS232 applications). Otherwise, with

multiple bussed units, a unique address number must be assigned to each meter.

The node address applies specifically to RS485 applications.

Select abbreviated transmissions (numeric only) or full field transmission.

When the data from the meter is sent directly to a terminal for display, the extra

characters that are sent identify the nature of the meter parameter displayed. In

this case, select



. When the data from the meter goes to a computer, it may be

desirable to suppress the node address and mnemonic when transmitting. In this

case, set this parameter to



.



- Enters the sub-menu to select those meter parameters to appear in the

block print. For each parameter in the sub-menu select



for the parameter to

appear with the block print, and



to disable the parameter.

Gross Value



 

Tare Value



 

Input Value



 

Max and Min Values



 

Total Value



 

Setpoint values



 