1 power wiring, 2 input signal wiring, Input a signal wiring – Red Lion PAXDP User Manual

Page 7: Unreg, Input b signal wiring

Advertising
background image

7

4.1 POWER WIRING

1

2

AC

AC

AC Power

Terminal 1: VAC
Terminal 2: VAC

1

2

DC+

DC-

+

-

DC Power

Terminal 1: +VDC
Terminal 2: -VDC

4.2 INPUT SIGNAL WIRING

Current Signal

(self powered)

Terminal 4: -ADC
Terminal 5: +ADC

Voltage Signal

(self powered)

Terminal 4: -VDC
Terminal 5: +VDC

Current Signal (2 wire

requiring excitation)

Terminal 3: +ADC

Terminal 5: -ADC

3

4

5

-

+

10 VDC MAX.

COMM.

+18 V EXC

.

INPUT

A

UNREG.

INPUT A SIGNAL WIRING

Voltage/Current Signal (3 wire requiring excitation)

Terminal 3: +Volt supply

Terminal 4: -ADC (common)

Terminal 5: +ADC (signal)

4

5

COMM.

INPUT

A

+

-

LOAD

3

4

5

COMM

.

+18 V EXC.

INPUT

A

3 WIRE TRANSMITTER

I/V

COMM.

+Vs

UNREG

.

3

4

5

+18 V EXC

.

INPUT

A

COMM.

2 WIRE

TRANSMITTER

+

-

UNREG.

Before connecting signal wires, the Input Range Jumper must be verified for proper position.

CAUTION: Sensor Input B common is NOT isolated from user input common. In order to preserve the safety of the meter application, the sensor input

common must be suitably isolated from hazardous live earth referenced voltages; or input common must be at protective earth ground potential. If not,

hazardous live voltage may be present at the User Inputs and User Input Common terminals. Appropriate considerations must then be given to the

potential of the user input common with respect to earth common; and the common of the isolated plug-in cards with respect to input common.

Current Signal

(self powered)

Terminal 7: -ADC
Terminal 8: +ADC

Voltage Signal

(self powered)

Terminal 7: -VDC
Terminal 8: +VDC

Current Signal (2 wire

requiring excitation)

Terminal 6: +ADC

Terminal 8: -ADC

6

7

8

-

+

10 VDC MAX.

COMM.

+18 V EXC

.

INPUT

B

UNREG.

INPUT B SIGNAL WIRING

Voltage/Current Signal (3 wire requiring excitation)

Terminal 6: +Volt supply

Terminal 7: -ADC (common)

Terminal 8: +ADC (signal)

7

8

COMM.

INPUT

B

+

-

LOAD

6

7

8

COMM.

+18 V EXC.

INPUT

B

3 WIRE TRANSMITTER

I/V

COMM.

+Vs

UNREG.

6

7

8

+18 V EXC

.

INPUT

B

COMM.

2 WIRE

TRANSMITTER

+

-

UNREG.

Advertising