The operating modes of the C48T are programmed using the front panel

keypad. (See page 12, for details on using the keypad to program the unit)
Accessibility to the Programming Menu depends on the Program Disable
Function setting (See page 11, for available program disable settings).

PROGRAMMING MENU

Numeric Value Entry Method

Configures push button response for entering numeric

data values such as Presets and Output Times

Timer Range

The timer range determines the time units to be used.

trAnGE

SEC.0

-13-

Timer Operating Mode

The charts on the following pages, show operating

modes for the Single Preset and Dual Preset Timer Models.
In the descriptions below, the “Main Preset” or “Output”
refers to “Preset 1” or “Output 1” on the Single Preset
Model. On the Dual Preset Model it refers to “Preset 2” or
“Output 2”.

Reset Type:

Auto - Unit automatically resets as programmed, when timer triggers main

preset’s output or at it’s timed output end.

Manual - Unit does not reset when timer triggers main preset’s output or at

it’s timed output end. The timer value can be manually reset by a User
Input or by Serial Communications command.

Reset to:

Zero - When reset (manually or automatically) timer value goes to zero. The

Main Preset Output is triggered when timer value reaches main Preset
Value.

Preset - When reset (manually or automatically), the main Preset value is

loaded into the timer value. The main Preset Output is triggered when
timer value reaches zero.

At Timed Output End:

When this mode is selected, Auto Reset occurs when the main preset’s
Output time elapses and the main output deactivates. If not selected, Auto
reset occurs when the main output is triggered.

Continue Timing at Main Output:

The timer continues timing when main output is triggered. To stop timing,
the “Run/Stop” terminal is put into the “Stop” state. This mode is useful for
repetitive, auto-cycling applications.

Stop Timing at Main Output:

The timer will stop when the main preset’s output is triggered. To resume
timing, a manual reset (User Input -

rSt-E

) is performed, which resets the

output and the stop condition. The Run/Stop input can also be used to restart
the timer by putting it in the “Stop” state and then back to the “Run” state.
Cycling the Run/Stop however, will not reset or affect any outputs. This
mode is used to provide “one-shot” capability.

OPEr

11

USER INTERFACE/PROGRAMMING MODES

MODE

DESCRIPTION

diGit

The digit entry method allows the selecting and
incrementing of each numeric digit on an
individual digit-by-digit basis.

AutoSc

EntrY

AutoSc

1 hour

0.01 hr
0.1 hr

1 min

0.1 min

999999 Hours

9999.99 Hours
99999.9 Hours

9999.59 Hours.Minutes

999.59.9 Hours.Minutes.0

h

h.00
h..0

h.n

h.n.0

0.01 min

99.59.99 Hours.Minutes.00

h.n.00

1 sec

99.59.59 Hours.Minutes.Seconds

h.n.SEC

0.1 sec

999.59.9 Minutes.Seconds.0

n.SEC.0

1 sec

9999.59 Minutes.Seconds

n.SEC

0.1 min

99999.9 Minutes

n.0

0.01 min

9999.99 Minutes

n.00

0.001 min

999.999 Minutes

n.000

1 sec

999999 Seconds

SEC

0.1 sec

99999.9 Seconds

SEC.0

0.01 sec

9999.99 Seconds

SEC.00

0.001 sec

999.999 Seconds

SEC.000

RESOLUTION

RANGE

MODE

The auto scrolling method allows pressing and
holding the “up” or “down” keys to progressively
change all digits of the data value, similar to
incrementing or decrementing a counter.