PrnOPt

3

Timer

Value

Preset

Values

PRINT

01

02

03

Serial Abbreviate Mnemonics

When transmitting data, the unit can be programmed to
suppress the address number, mnemonics, and some spaces
by selecting

YES

for this parameter. A selection of

YES

results in a faster transmission and may be useful when
interfacing with a computer. However, when interfacing
with a printer, sending mnemonics is usually desirable.

Print Options

The Print Options parameter determines which values

are printed in response to a Print Request command or user
input print request.

Serial Baud Rate and Parity Settings

This parameter configures the Baud Rate and Parity

Settings for RS485 Serial Communications.

Serial Unit Address (00-99)

This parameter configures the Serial Unit Address. This

address is used to uniquely identify each unit when multiple
units are connected on an RS485 bus.

-21-

SErSEt

96n

SErAdr

0

SErAbr

no

DESCRIPTION

12n

1200 Baud; No Parity (8 data bits)

12o

1200 Baud; Odd Parity (7 data bits)

12E

1200 Baud; Even Parity (7 data bits)

24n

2400 Baud; No Parity (8 data bits)

24o

2400 Baud; Odd Parity (7 data bits)

24E

2400 Baud; Even Parity (7 data bits)

48n

4800 Baud; No Parity (8 data bits)

48o

4800 Baud; Odd Parity (7 data bits)

48E

4800 Baud; Even Parity (7 data bits)

96n

9600 Baud; No Parity (8 data bits)

96o

9600 Baud; Odd Parity (7 data bits)

96E

9600 Baud; Even Parity (7 data bits)

MODE

MODE

DESCRIPTION

no

YES

Unit sends Serial Address, Value Mnemonic, and
right justified numeric value when a serial
Transmit Value command, a Print Request
command, or User Input Print Request is issued.
A 400 msec “printer delay” is inserted between
each value when a Serial Print Request command
or User Input Print Request is performed.

Only the numeric data value is transmitted when a
serial Transmit Value command, Print Request
command or User Input Print Request is issued.
No unit address, mnemonics, or 400 msec printer
delay are transmitted. This option is beneficial
when communicating with a computer and faster
data throughput is desired.

MODE

NUMBER

The next five parameters pertain to serial communications and are only

found on Dual Preset units with the RS-485 serial option installed.