background image

Electronic Controller Solutions for the Global Fluid Power Industry

Hydraulic Fan System Controller with SAE J1939 Interface

HFS-J User Guide

Part No:-

021-00158 Rev C

HFS-J Hydraulic Fan System Controller User Guide

Page | 10

Application Examples:


NOTE:-

Controller MUST have

in-line fuse fitted by

user in +V Power Input

for system protection.

Pin 1:- Thermistor #1 +signal input.
Pin 2:- Thermistor #2 +signal input.
Pin 3:- CAN_H Input ( J1939 )
Pin 4:- CAN_L Input ( J1939 )
Pin 5:- +Vin 9 to 32VDC Power supply Input
Pin 6:- Reverse fan input ( Momentary )
Pin 7:- 0V power input ( Common )
Pin 8:- 0V—Signal common #1
Pin 9:- 0V—Signal common #2
Pin 10:- Alarm output drive ( 3A max sourcing )
Pin 11:- Reverse valve output drive ( 3A max sourcing )
Pin 12:- Proportional valve output ( 3A max sourcing )

NOTE:-

View looking at 12 way male connector on

HFS - J

controller -

DTF15-12PB