Error led code descriptions – High Country Tek HFS-J-Bus User Manual

Page 11

Advertising
background image

Electronic Controller Solutions for the Global Fluid Power Industry

Hydraulic Fan System Controller with SAE J1939 Interface

HFS-J User Guide

Part No:-

021-00158 Rev C

HFS-J Hydraulic Fan System Controller User Guide

Page | 11

Error LED code descriptions:

Status LED

Reverse / Error LED

Discription

Alarm Output

Fan Output

Reverse Output NOTE

OFF

OFF

Power Supply < 9.3 VDC

OFF

OFF

OFF

1

OFF

OFF

Power Supply > 30 VDC

OFF

OFF

OFF

1

ON

OFF

Normal Operation

OFF

As Demanded

As Demanded 2

ON

OFF

J1939 RPM Timeout

OFF

Min Current

As Demanded 3

ON

OFF

Reverse Sequence Active

OFF

Reverse SPD %

ON

2

ON

Flashing

J1939 Engine Coolant Timeout

ON

Min Current

As Demanded 3

ON

Flashing

J1939 Transmission Temp Timeout

ON

Min Current

As Demanded 3

ON

Flashing

J1939 Intake Man. Temp. Timeout

ON

Min Current

As Demanded 3

Code = 1

Flashing

J1939 Engine Coolant Over Temp

ON

Min Current

As Demanded 3, 7

Code = 2

Flashing

J1939 Intake Man. Over Temp

ON

Min Current

As Demanded 3, 7

Code = 3

Flashing

J1939 Transmission Over Temp

ON

Min Current

As Demanded 3, 7

Code = 1

Flashing

PWM Output Open

ON

Min Current

OFF

4

Code = 2

Flashing

PWM Output Short

ON

Min Current

OFF

4

Code = 3

Flashing

Alarm Output Short

OFF

Min Current

OFF

3

Code = 5

Flashing

Reverse Output Short

ON

Min Current

OFF

3

Code = 1

Flashing

Unit Temp >80°C

OFF

OFF

OFF

5

Code = 3

Flashing

Thermistor 1 Short

ON

Min Current

OFF

6

Code = 4

Flashing

Thermistor 1 Open

ON

Min Current

OFF

6

Code = 5

Flashing

Thermistor 1 Over Temp

ON

Min Current

OFF

6, 8

Code = 6

Flashing

Thermistor 2 Short

ON

Min Current

OFF

6

Code = 7

Flashing

Thermistor 2 Open

ON

Min Current

OFF

6

Code = 8

Flashing

Thermistor 2 Over Temp

ON

Min Current

OFF

6, 8

NOTES:

1

Wait for Correct Power

2

Normal Operation

3

Fan Output min current until corrected (Max Fan SPD)

4

Attempt to drive min current to fan until corrected

5

Wait until unit temp < 70°C

6

Fan Output min current until corrected (Max Fan SPD) Reverse Sequence Cancled

7

Reverse Cycle Operates Normaly

8

Reverse Cycle Normal If Reverse Input Switch is used and Overtemp Condition is present before start of cycle

Advertising
This manual is related to the following products: