C

ONNECTING

TO

A

R

EGULATED

P

OWER

S

UPPLY

To connect the transceiver to an appropriate regulated
DC power supply, use an optional PG-2W DC cable.

1 Confirm that the power of both the transceiver and

the DC power supply is OFF.

2 Connect the optional PG-2W DC cable to the DC

power supply; the red lead to the positive (+)
terminal, and the black lead to the negative (–)
terminal.

3 Connect the barrel plug on the DC cable to the

DC IN jack of the transceiver.

While a DC power supply is connected with the DC IN
jack, the transceiver automatically initiates charging the
PB-43N Ni-MH battery pack.

Note:

◆

If the DC power supply voltage is below 12.0 V DC, you may not
be able to charge the PB-43N Ni-MH battery pack.

◆

The supply voltage must be between 12.0 V and 16.0 V to
prevent damaging the transceiver. If the input voltage exceeds
approximately 16.5 V, warning beeps sound and “DC ERR”
appears. Remove the DC IN jack plug immediately.

◆

If the DC power supply voltage is above 14.5 V DC and “

”

(High Power) is selected, the “

” icon blinks and the output

power is gradually reduced to “

” level (Medium Power)

{page 95}.