Performing program scan – Kenwood TH-K2E - Discontinued User Manual

Page 76

Advertising
background image

62

4 Press [MR] to store the start frequency in the

memory channel.

5 Turn the Tuning control to select your desired

end frequency.

6 Press [F], [MR] then turn the Tuning control to

select a channel from U0 ~ U2, corresponding to
the channel selected in step 4.

For example, if you selected L0 in step 4, select U0
for the end frequency.

7 Press [MR] to store the end frequency in the

memory channel.

Performing Program Scan

1 Press [VFO].

2 Turn the Tuning control to select a frequency

within the frequency range of memory channel
L0/U0 ~ L2/U2.

3 Press [VFO] (1 s) to start Program Scan.

4 To stop Program Scan, press [VFO] or [PTT].

Note:

If you press [MONI/SQL], Program Scan temporarily pauses.
Release [MONI/SQL] to resume scanning.

The transceiver stops scanning when it detects a signal.

If more than 2 Program Scan channel pairs are stored and
overlaps the frequency range among the pairs, the smaller
Program Scan memory channel number has priority.