Anritsu MG3641A User Manual

Page 137

Advertising
background image

SECTION 6 GPIB

6-31

:FREQuency:SWEep:TIME <Numeric> <Time term>

Function

Sets the sweep time for a frequency sweep.

Parameter

<Numeric> = 0.1 ms to 600 s

Unit

<Time term>

Restriction

None

:FREQuency:SWEep:TIME?

Function

Reads out the sweep time for a frequency sweep.

Response

Sweep time for a frequency sweep

Restriction

None

:FREQuency:SWEep:MARKer <Numeric> <Freq term>

Function

Sets the marker frequency for a sweep.

Parameter

<Numeric> = 0.01 Hz to 1040 MHz (MG3641A)

0.01 Hz to 2080 MHz (MG3642A)

Unit

<Freq term>

Restriction

None

:FREQuency:SWEep:MARKer?

Function

Reads out the marker frequency for a sweep.

Response

Marker frequency for a sweep

Restriction

None

:FREQuency:SWEep:PATTern

Function

Sets the frequency sweep pattern.

Parameter

<Character> = SIZE

NO
LOG

Unit

<Non term>

Restriction

None

:FREQuency:SWEep:PATTern?

Function

Reads out the frequency sweep pattern.

Response

Frequency sweep pattern = SIZE

NO
LOG

Restriction

None

:FREQuency:SWEep:TYPE <Numeric>

Function

Sets the frequency sweep type.

Parameter

<Numeric> = 0 (START-STOP)

1 (CENTER-SPAN)

Unit

<Non term>

Restriction

None

:FREQuency:SWEep:TYPE?

Function

Reads out the frequency sweep type.

Response

Frequency sweep type = 0 (START-STOP)

1 (CENTER-SPAN)

Restriction

None