:MEMory:SWEep:STARt?

Function

Reads out the start address for a sweep.

Response

Start address for a sweep.

Restriction

None

:MEMory:SWEep:STOP : <Numeric>

Function

Sets the stop address for a sweep.

Parameter

<Numeric> = 0 to 999

Unit

<Non term>

Restriction

None

:MEMory:SWEep:STOP?

Function

Reads out the stop address for a sweep.

Response

Stop address for a sweep.

Restriction

None

:MEMory:SWEep:MODE <Character>

Function

Selects the memory sweep mode.

Parameter

<Character> = AUTO

SINGLE
MANUAL

Unit

<Non term>

Restriction

None

:MEMory:SWEep:MODE?

Function

Reads out the memory sweep mode.

Response

Memory sweep mode =

AUTO
SINGLE
MANUAL

Restriction

None

:MEMory:SWEep:TIME <Numeric>

Function

Sets the sweep time for a memory sweep.

Parameter

<Numeric> = 0.1 ms to 600 s

Unit

<Time term>

Restriction

None

:MEMory:SWEep:TIME?

Function

Reads out the sweep time for a memory sweep.

Response

Sweep time for a memory sweep.

Restriction

None

:MEMory:SWEep:MARKer < Numeric>

Function

Sets the marker memory for a sweep.

Parameter

<Numeric> = 0 to 999

Unit

<Non term>

Restriction

None

:MEMory:SWEep:MARKer?

Function

Reads the marker memory for a sweep.

Response

Marker memory for a sweep.

Restriction