Section 4. Commands

11

SWB PARAMETERS

The SWB functions are listed in Table 4-2 and described below.

Control Characters and MICR Data

Control Characters may be added to the MICR data message. The characters are always in the
following locations:

<STX> <ESC> data <ETX> <CR> <LF>


The control characters, descriptions, and hex values are shown in Table 4-3.

Table 4-3. Control Characters

CONTROL

CHARACTER

DESCRIPTION

HEX VALUE

<STX>

Start of Text

02

<ESC> Escape

1B

<ETX>

End of Text

03

<CR> Carriage

Return

0D

<LF> Line

Feed

0A


For example, if <STX> and <CR> are set to YES, the message from the MICR Reader will look
like this:

MICR Data: <STX>data<CR>


Control Characters and Card Data

The control characters are also available for card data but they are applied to each track
individually. For example, if the <STX> and <ETX> options are set to YES, the card data
message is transmitted as follows:

Card Data: <STX>[TK1 data]<ETX><STX>[TK2 data]<ETX><STX>[TK3 data]<ETX>

Communication Modes

The selection of comm modes is a quick way of selecting multiple Control Characters. For
instance, to send a carriage return/line feed pair after the data, you can specify Comm Mode 3.

Advertising