MagTek MAXI MICR RS232 User Manual

Page 50

Advertising
background image

MAXI MICR RS232 with 2-Track MSR

42



13

No MICR data detected

Possible causes for this problem are:
• No MICR characters - the ink used to print the MICR characters does not have magnetic

properties. Try one of the sample checks provided by MagTek.

• Feeding the check - When feeding the check, make sure that the MICR line is at the bottom

and the printed side of the check is facing the MagTek logo on the MICR Reader.


Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 14.



14

Cable problem


Possible causes for this problem are:
• Loose connection - the cable connector on the PC or the MICR Reader may be loose. Make

sure that both connectors are tightly connected.

• Damaged cable - the connectors, pins or wires in the cable may be damaged. Replace cable.

Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 17.



15

No problem found


The MICR Reader is operating properly. If you have additional concerns or requirements please
contact your MagTek representative.



16

Read Insta-Change check


Read Insta-Change check with the appropriate settings. Return to step 00. If condition persists,
continue to step 17.

Advertising