MagTek MAXI MICR RS232 User Manual

Page 48

Advertising
background image

MAXI MICR RS232 with 2-Track MSR

40


Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 14.



07

Missing characters


Possible causes for this problem are:
• Character rate - the character rate at which the MICR Reader is transmitting data may be too

fast for the PC. Use SET-MICR to set the "Inter-character Delay" option to YES.

• Feeding the check - When feeding the check, make sure that the MICR line is at the bottom

and the printed side of the check is facing the MagTek logo on the MICR Reader.


Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 08.



08

Communication parameters do not match


Verify that the communication parameters of the MICR Reader match the parameters of the PC.
Use SET-MICR to verify/change the communication parameters.

Determine if the condition described above is true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 14.



09 Incorrect

Format


Possible causes for this problem are:
• Incorrect Format Number - the current Check data format in the MICR Reader is not the

desired format. Use SET-MICR to verify/change the format.

• Incorrect Message Format - the current Message format in the MICR Reader is not the

desired format. Use SET-MICR to verify/change the Message format.


Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 17.

Advertising