Horner APG XL7 OCS User Manual

Page 56

Advertising
background image

XL7 User Manual

Warning = Time and date need to be set

I/O System

Ok = I/O configuration matches the installed I/O and COM modules

Warning = I/O configuration needs updating to match installed modules

Battery

Ok = Backup battery operating properly

Warning = Backup battery needs to be replaced

View I/O Slots

The View I/O Slots Sub-Menu displays three System Settings, none of which may be edited.

Internal to the XL7 OCS, there is a CPU board, and up to two installed modules. Model XW100 has no

installed I/O or COM modules. All other models have an I/O module and can have a user-installed COM

module.

Depending on which I/O module is installed and which I/O module has been configured by Cscape, one

of the following six System Settings should appear for Slot 1:

Slot 1: I/O: Empty

= No I/O module installed or configured

Slot 1:*Unsupported

= Unsupported I/O module installed

Slot 1:-I/O Missing

= No I/O module installed but an I/O module is configured

Slot 1:+I/O: XExyy

= yy I/O module installed but no I/O module configured

Slot 1:?I/O: XExyy

= yy I/O module installed but another I/O module configured

Slot 1: I/O: XExyy

= yy I/O module installed and configured properly

Depending on the COM module that is installed and the COM module that has been configured by

Cscape, one of the following six System Settings appears for Slot 2:

Slot 2: I/O: Empty

= No COM module installed or configured

Slot 2:*Unsupported

= Unsupported COM module installed

Slot 2:-I/O Missing

= No COM module installed but a COM module is configured

Slot 2:+I/O: XzC

= z COM module installed but no COM module configured

Slot 2:?I/O: XzC

= z COM module installed but another COM module configured

Slot 2: I/O: XzC

= z COM module installed and configured properly

Slot 3: I/O: ETN300

= ETN300 has been configured through Cscape

Page 56 of 110