Campbell Scientific EasyAG Probe for Soil Volumetric Water Content Profiles User Manual

Page 13

Advertising
background image

EasyAG

®

Soil Water Content Profile Probes

Sample CR10X Program

Shaded portions of program can be omitted if TriSCAN sensors are not used.

;CR10X Datalogger
;Program Author: Campbell Scientific, Inc.
;Date: 04-12-06

;Description:

Program measures 1 EnviroSMART / TriSCAN probe with 8 sensors or 1 EasyAG

;

TriSCAN probe with 4 sensors. -1000 is loaded as the "measurement" for

;

non-existant sensors. Program measures scaled frequencies, calculates

;

water contents, and stores scaled frequencies, water contents, and

;

volumetric ion contents separately. Scaled frequencies are stored with an

;

"array identifier" leading 8 data values per record followed by 8 VIC per

;

record, with the record ending with zero rain and irrigation values for

;

compatibility with DBLOAD & Irrimax software.


;Assumptions:

EnviroSMART or EasyAG probe SDI-12 interface is configured to output

;

scaled frequencies


;Wiring:

EnviroSMART / EasyAG 12 Volts (Pin 1)--------- CR10X 12 V

;

EnviroSMART / EasyAG Ground (Pin 2)-------- CR10X Ground

;

EnviroSMART / EasyAG Signal (Pin 3) --------- C7


;

Rain Gage Pulse Out -------------------------------- CR10X P2

;

Rain Gage Ground ----------------------------------- CR10X Ground



;{CR10X}
;
*Table 1 Program
01: 30

Execution

Interval

(seconds)


;Load Scaled Frequency to Water Content Co-effecients

a = .1957
b = .404
c = .02852

;Preload missing sensor error

1: Beginning of Loop (P87)
1: 0

Delay

2: 8

Loop

Count


2: Z=F x 10^n (P30)

1: -1000

F

2: 0

n, Exponent of 10

3: 1

-- Z Loc [ ES1_SF_1 ]

9

Advertising