Specifications – Campbell Scientific EasyAG Probe for Soil Volumetric Water Content Profiles User Manual
Page 8
EasyAG
®
Soil Water Content Profile Probes
6. Specifications
Feature
EasyAG
®
SDI-12
Maximum cable length to
logger or third party device
60 m (200 ft)*
Maximum sensors per standard
probe
4
Sensor Measuring Principle
High frequency capacitance
Output Options
SDI-12
Protocol options
SDI-12
Interface Measuring Principle 16 Bit pulse count
Output Resolution
16 Bit
Output Method
Serial data
Current Consumption
250 µA @ Sleep
66 mA @ Standby
100 mA @ Sampling
Reading range
Water Content/Salinity
0 to ~65%/0 to 17 dSm
-1
Temperature effects
±3% 5°C to 35°C
Operating temperature range
-20°C to +75°C
Time to read one sensor
1.1 seconds
Sphere of influence
99% of the reading is taken within a 10 cm
radius from the outside of the access tube
Sensor diameter
26.5 mm
Access tube diameter
32 mm
Probe length
50 cm (20 inches)
* Based on SENSDI12CBL-L cable.
4