Applications, 1 working around firewalls, 1 configuring the nl240 – Campbell Scientific NL240 Wireless Network Link Interface User Manual

Page 39: Working around firewalls, Configuring the nl240, 1. working around firewalls

Advertising
background image

NL240 Wireless Network Link Interface

If the status of the TLS stack is

Initialized, the NL240 will

automatically negotiate a secure TLS connection with DevConfig

as long as the

Use IP Connection option is selected.

Encrypted Communication is required to change the TLS Private

Key and/or TLS Certificate via TCP. The private key and

certificate cannot be initialized via TCP, since the connection is

not encrypted. They must be initialized through a direct USB

connection to the NL240.

When the NL240 is in bridge mode, it cannot be configured via a

secure network connection, because in bridge mode the TLS stack

is not initialized. It can be configured via USB, RS-232, or an

unsecured network connection.

9. Applications

9.1 Working Around Firewalls

The NL240 can be used to provide a connection between LoggerNet and a

datalogger when both are behind firewalls. The NL240 must be on a public IP

address and will act as a common meeting place for all PakBus®

communications.

FIGURE 9-1. Working around firewalls

9.1.1 Configuring the NL240

Connect to the NL240 in DevConfig (see Section 7, Configuring the

NL240).

On the NL240 tab:

o Set Bridge Mode to disable.

o Set Use DHCP to disable.

NOTES

29

Advertising