RTMC Pro

Clicking on an interval parameter provides a drop-down arrow that can be used
to select one of the predefined time constants. After selecting one of the
predefined time constants, you can click in the edit box and modify the value.

es not

Aliases

If a data value is used multiple times in an expression, the expression can be

d by declaring an alias for the data value. Use the Aliases tab to

declare aliase(s) to be used in the expression.

For example, you can choose nsecPerMin, and then click in the box to modify
this to 30*nsecPerMin. Note that one of the predefined time constants do
have to be used. You can type in an interval directly.

All other parameters must be typed in directly.

simplifie

On the Aliases side tab, select the New button (

) to add an alias. Selec

alias and press the Delete button (

t an

) to delete an alias. Use the arrow buttons

to move an alias up or down in the list. Selecting an alias and then clicking on

e

h

on as shown below. The alias is inserted into the

expression by typing it directly, double-clicking on the alias, or right-clicking

the alias name will allow you to edit the alias nam . Selecting an alias,
clicking on the data value field, rig t-clicking, and choosing Browse… will
bring up a Data Source Browser window that can be used to browse to the data
value to be aliased.

Once a data value has been aliased, the alias can be used in place of the data
value in the expressi

on the alias and selecting Insert alias_name into expression.

ValueSynch

The ValueSynch function can be used to synchronize data values coming from

sources so that you can display the results of a calculation on

those data values in a single component.

multiple data