Second command option (parameter 6) – Campbell Scientific SDM-SIO4 4-Channel Serial I/O Interface User Manual

Page 44

Advertising
background image

Section 5. Programming the Datalogger

5-12

Handshake Mode:
0

Leave as set previously

1

DTR always set, set RTS when data is available to transmit, only
transmit if CTS is set

2

DTR always set, RTS always set, only transmit if CTS is set

3

DTR and RTS always set, ignore CTS

4

XON/XOFF data flow control

9

No automatic handshake (leaves lines in previous state)

Stop Bits and Parity:
0

Leave as set previously.

1

1 stop bit no parity.

2

1 stop bit even parity.

3

1 stop bit odd parity.

4

1.5/2 stop bits no parity.

5

1.5/2 stop bits even parity.

6

1.5/2 stop bits odd parity.

Data Length:
0

Leave as set previously

1

5 data bits

2

6 data bits

3

7 data bits

4

8 data bits

Baud Rate:
0

Leave as set previously

1

300 baud

2

600 baud

3

1200 baud

4

2400 baud

5

4800 baud

6

9600 baud

7

19200 baud

8

32400 baud

9

76800 baud

Second Command Option (Parameter 6)

This option is used to set the handshaking delay in units of 50ms. The accuracy
is -50ms, +0ms. The range is 0-254, with 255 reserved for XON /XOFF mode.
XOFF will force the SDM-SIO4 to wait indefinitely for an XON.

When the SDM-SIO4 is reset from the ‘command line’, the ports
are set to 9600 baud, 8 data bits, 1 stop bit, no parity and no
handshake as the default.

A 1ms delay is required after Command 2049 before the next SDM-
SIO4 command is initiated.

NOTE

NOTE