Table 11, At-a-glance specifications – ADTRAN TRACER 5045 User Manual

Page 30

Advertising
background image

Section 3 Engineering Guidelines

TRACER 5045 System Manual

30

© 2004 ADTRAN, Inc.

612805045L1-1B

Table 11. At-A-Glance Specifications

Hardware

Description

Specification

Transmitter

Output Power

+20 dBm, max

Frequency Range

5725 to 5850 MHz

Receiver

Receive Level, Minimum

-78 dBm

Receive Level, Maximum

-30 dBm

Receive Level, Nominal

-55 dBm

Frequency Plan

Plan A

Tx 5.747 GHz, Rx 5.827 GHz

Plan B

Tx 5.827 GHz, Rx 5.747 GHz

10/100BaseT/TX Interfaces

Connection

four RJ-48C jacks with auto MDI/MDIX crossover

Flow Control

backpressure flow control on all full-duplex interfaces

User Interface

Panel

Alarm LEDs

Diagnostics

RF link diagnostics and error history, transmit and
receive packets history

Test Points

RSSI and Ground (GND)

Alarms

Normally Open (NO) and Normally Closed (NC)

VT100 Terminal

Menu Driven User Interface, Control of the Remote
End, Optional Password Protection, Event History,
Ethernet Statistics

VT100 Terminal Interface

Data Rate

9600 bps

Data Bits

8

Parity

None

Stop Bits

1

Terminal Emulation

VT100

Mechanical and Environmental

Operating Temperature

-25° C to 65° C

Size

17.22” W x 9.34” D x 1.72” H

Humidity

95%, Non-condensing

Weight

7 lbs