AMX NetLinx Integrated Controllers NXI-x000 Series User Manual

Page 11

Advertising
background image

Introduction

7

NI-2000, NI-3000, NI-4000 Hardware Reference Guide

NI-3000 Specifications

Dimensions (HWD):

• 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)
• 2 RU (rack unit) high

Power Requirement:

• 900 mA @ 12 VDC

Memory:

• 32 MB SDRAM
• 1 MB of Non-volatile Flash

Compact Flash:

• 32 MB Card (upgradeable). Refer to the Other AMX Equipment section on

page 9 for more information.

Weight:

• 4.55 lbs (2.06 kg)

Enclosure:

• Metal with black matte finish

Certifications:

• FCC Part 15 Class B and CE

Front Panel Components:

LINK/ACT

• Green LED lights when the Ethernet cable is connected and an active link

is established. This LED also blinks when receiving Ethernet data packets.

Status

• Green LED lights to indicate that the system is programmed and

communicating properly.

Output

• Red LED lights when the Controller transmits data, sets channels On/Off,

sends data strings, etc.

Input

• Yellow LED lights when the Controller receives data from button pushes,

strings, commands, channel levels, etc.

RS-232/422/485 LEDs

Seven sets of red and yellow LEDs light to indicate the rear DB9 Ports 1-7

are transmitting or receiving RS-232, 422, or 485 data:

- TX LEDs (red) light when transmitting data

- RX LEDs (yellow) light when receiving data

- LED activity reflects transmission and reception activity

Relay LEDs

Eight red LEDs light to indicate the rear relay channels 1-8 are active

(closed)

• These LEDs reflect the state of the relay on Port 8
• If the relay is engaged = LED On and if the relay is Off = LED Off

IR/Serial LEDs

Eight red LEDs light to indicate the rear IR/Serial channels 1-8 are

transmitting control data on Ports 9-16

• LED indictor for each IR port remains lit for the length of time that IR/Serial

data is being generated

I/O LEDs

Eight yellow LEDs light when the rear I/O channels 1-8 are active
• LED indicator for each I/O port reflects the state of that particular port

Rack-mount brackets

• Provide an installation option for the Integrated Controller to be mounted

into an equipment rack, when used with the Installation Kit (KA2105-01).

Rear Panel Connectors:

RS-232/422/485 (Ports 1 -7)

Seven RS-232/422/485 control ports using DB9 (male) connectors with

XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.

• Channel range = 1-255
• Channels 1-254 provide feedback
• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a

'CTSPSH' command was sent to the port

• Output data format for each port is selected via software
• Seven DB9 connectors provide RS-232/422/485 termination

ICSNet

Two RJ-45 connectors for ICSNet interface

ICSHub Out

• RJ-45 connector provides data to another Hub connected to the Controller

Advertising