QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 12.

S U B T I T L E

T I T L E

E L E C T R I C A L

I N S T A L L A T I O N

This appliance must be branch circuit protected

with proper ampacities, in accordance with the

wiring diagram. The Quickchiller must be properly

grounded in accordance with the National Electrical

Code and applicable local codes. Wire size for the

main incoming power to the unit must match the

minimum size listed in the specifications applicable

to the specific Quickchiller model. For supply

connections, locate the wire size listed in this manual.
Before operating the chiller, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.
NOTE:

After electrical connections have been

completed, operate the appliance in any

chilling mode for a period of 15 minutes

and recheck the main power connections

at the terminal block to make certain they

remain tight.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

D A N G E R

ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

voltage

phase

cycle

/

hz

QC-3

QC-20

QC-40

QC-50

QC-100

SELF-CONTAINED

208-240VAC 1 ph 50/60 Hz

r

ecoMMeNded

circuit

aMperage

:

r

ecoMMeNded

wire

size

:

20 amps

12/2 w.g.

20 amps

12/2 w.g.

30 amps

10/2 w.g.

40 amps

8/2 w.g.

60 amps

6/2 w.g.

n o

c o r d

a n d

p l u g

voltage

phase

cycle

/

hz

QC-3

QC-20

QC-40

QC-50

QC-100

SELF-CONTAINED

208-240VAC 3 ph 50/60 Hz

r

ecoMMeNded

circuit

aMperage

:

r

ecoMMeNded

wire

size

:

Not

available

Not

available

Not

available

20 amps

12/3 w.g.

40 amps

8/3 w.g.

380-415VAC 3 ph 50/60 Hz

r

ecoMMeNded

circuit

aMperage

:

r

ecoMMeNded

wire

size

:

Not

available

Not

available

30 amps

10/2 w.g.

Not

available

30 amps

10/2 w.g.

n o

c o r d

a n d

p l u g

voltage

phase

cycle

/

hz

QC-3

QC-20

QC-40

QC-50

QC-100

REMOTE COMPRESSOR

(Cabinet Only)

208-240VAC 1 ph 50/60 Hz

r

ecoMMeNded

circuit

aMperage

:

r

ecoMMeNded

wire

size

:

Not

available

Not

available

Not

available

20 amps

12/2 w.g.

30 amps

10/2 w.g.

n o

c o r d

a n d

p l u g

ELECTRICAL SPECIFICATIONS

Wire diagrams are located near the top of the unit, close to the compressor or control panel.