INSTALLATION REQUIREMENTS

The model QC-3 is a counter mounted unit and

must be sealed to the counter with a NSF listed

silicone sealant.

For all other

models, install

the appliance

on a smooth and

level floor surface. Use the adjustable

cabinet legs to level the Quickchiller.
Adjust from front-to-back and from side-to-side

with the use of a spirit level to evenly distribute

the cabinet weight and avoid pulling the cabinet

alignment out of square.
After leveling the cabinet of cart equipped models,

check the height relationship of the roll-in cart

to the cabinet. Adjust the Quickchiller height as

needed to accommodate the cart and to securely

close the Quickchiller door(s).

DOOR SEAL:
Check the door gasket to make certain it is sealing

properly and that the gasket provides an even and

positive seal around the entire door frame.

WATER DRAINAGE

A 1/2" I.D. (12,7mm) PVC pipe is furnished with

each QC-50 and QC-100 model. Use PVC glue

to attach the pipe into the drain opening at the

rear of the unit. Insert the PVC pipe into the

drain opening with a 1/4" (6mm) clockwise turn.

Connect the PVC pipe to discharge through an

indirect waste pipe into an open-site drain by

means of a 2" (51mm) air gap. Connection must

be within 10' (3m) of the unit.

NOTE:

In the U.S.A., this equipment is to

be installed to comply with the Basic

Plumbing Code of the Building Officials

and Co de Administrators International,

Inc. [BOCA], and the Food Service

Sanitation Manual of the Food & Drug

Administration [FDA].

DRAINAGE:

QC-3

QC-20

QC-40

EVAPORATOR PANS: NO INSTALLATION REQUIRED

QC-50 QC-100

ONE (1) FLOOR DRAIN:

1/2" (12,7mm) DIAMETER

C A U T I O N

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

drain

opening

at

rear

I N S T A L L A T I O N