USER SETTINGS

changing user settings

Starting from the

off

position, press the power key

on

. The Alto-Shaam name will illuminate and the

SELECTION SCREEN

will appear on the display.

The compressor will become energized and will

begin to operate if required by the sensors.
Press the PROGRAM key. The display will

indicate the User Settings each time the Program

key is pressed.

Press the up

5

or down

6

arrow keys to select the desired

User Setting.
Press the right

4

or left

3

arrow keys to change the value.

Press the PROGRAM key to save settings and

return to the SELECTION SCREEN.

programming user settings
1. START MANUAL DEFROST

Select Start Manual Defrost and press the

START/STOP

key to initiate a manual defrost

cycle. The defrost cycle will complete operation

when the temperature of the coil or coils reach set-

point values or after a period of 20 minutes,

whichever occurs first.

2. DEFROST FREQUENCY

The display will indicate the length of time necessary

to accrue before the Fan Timer triggers an automatic

defrost cycle. This period of time can be adjusted by

pressing the right

4

or left

3

arrow keys to to increase

or decrease automatic defrost cycle time (4-10 hours).

3. LANGUAGE

The display will indicate the currently selected

language. Press the right

4

or left

3

arrow key to select

English, Spanish, or French as the language of choice.

4. DATE

The display will indicate YEAR, MONTH, and DAY

OF MONTH (YYYY/MM/DD). Press the up

5

or

down

6

arrow key to select the date, time, and day,

and the right

4

or left

3

arrow key to increase or

decrease the numbers as required.

5. TIME

The display will indicate the current TIME of day

(HH:MM). Press the up

5

or down

6

arrow key to select

the hours or minutes and the right

4

or left

3

arrow key

to increase or decrease the numbers as required.

6. °F/°C - Fahrenheit/Celsius

The display will indicate a choice between Celsius

and Fahrenheit for Quickchiller temperature display

readings. Press the right

4

or left

3

arrow key to

toggle the setting.

7. HOLD DEFAULT

The display will indicate the default HOLD

temperature. Press the right

4

or left

3

arrow key to

increase or decrease the default holding temperature

between a range of -5°F to +40°F (-21°C to +4°C).

8. HACCP ADDRESS

The display will indicate the HACCP Address

Number. This item allows the operator to assign a

specific identifying number (1 to 247) to the individual

Quickchiller as part of a serial communication interface

for the web-based, HACCP with Kitchen Management

software package option. Press the right

4

or

left

3

arrow key to increase or decrease the number.

9. PROBE VERIFICATION

With the probe verification selected, press the Start key

to enter the probe verification mode.

The display will show the offset and the temperature of:

Top Probe (

where

applicable

)

Middle Probe (

where

applicable

)

Bottom Probe (

where

applicable

)

If probe calibration is needed, place the probe

in a glass of ice-water and let the probe settle in

temperature. The temperature in the glass should be

32°F (0°C).
To calibrate, Press up

5

or down

6

arrow key to adjust

between the probes, and the right

4

or left

3

arrow

keys to adjust the calibration value.

Press the PROGRAM key to exit probe

calibration mode.

10. PRESETS

(0=

UNLOCKEd

, 1=

LOCKEd

)

I

o

If the presets are locked, pressing

start

on

the desired preset will skip the mode overview

and will start immediately. Factory default

is

locked

.

11. CHILL MODES

(0=

UNLOCKEd

, 1=

LOCKEd

)

I

o

If the chill modes are locked, pressing the

chill mode button will skip the mode overview

and will start immediately. Factory default

is

unlocked

.

12. FACTORY RESET

Resets all presets and user-defined settings to factory

default settings. Warning: Pressing Factory Reset will

erase all User Settings and Presets programmed by

the user. All custom User Settings and Presets will

need to be reprogrammed.

A D V A N C E D O P E R A T I O N

O P E R A T I O N

USER SETTINGS

1.

Start Manual Defrost

7.

Default Hold Temperature

2.

Defrost Frequency

8.

HACCP Address

3.

Language

9.

Probe Verification

4.

Date - YYYY/MM/DD

10.

Presets

5.

Time - HH:MM

11.

Chill Modes

6.

°F/°C - Fahrenheit/Celsius 12. Factory Reset

A D V A N C E D O P E R A T I O N