SOFT CHILL … To rapidly decrease the

temperature of foods by internal product

probe temperature or time within a

range of 24°F to 36°F (-4°C to 2°C). Soft

Chill is recommended for less dense

food items that chill quickly. The mode

automatically converts to a refrigerated

holding temperature at the end of the

chill cycle.

B

a

f

c

b

e

d

g

HOLD TEMP … The mode for

refrigerated storage within a temperature

range of -5°F to +40°F (-21°C to +4°C).

Hold Temp offers continuous refrigerated

storage without the utilization of food

probes or a timer. Hold Temp always

defaults to the default hold temperature,

found under the User Settings.

C

HARD CHILL … To rapidly decrease the

temperature of foods by internal product

probe temperature or time within a range

of 11°F to 23°F (-11°C to -5°C). Hard

Chill is recommended for more dense

food items. The mode automatically

converts to refrigerated holding

temperature at the end of the chill cycle.

D

QUICK FREEZE … The mode for rapid

freezing and frozen food maintenance by

internal product probe temperature or

time within a temperature range of

-10°F to +10°F (-23°C to -12°C). The mode

automatically converts to a frozen food

holding temperature at the end of the

quick freeze cycle.

E

start/stop … Button used to

initiate operating modes, set time and

temperatures, and to set specific chiller

program functions.

F

program … Button used to modify or

select specific chiller programming functions.

G

on

/

off

power

button

.