Vertical contact toaster, Hi use, Chec – A.J. Antunes & Co VCT-2000 9210410 User Manual

Page 11: Operation (continued), Fault messages

Advertising
background image

11

VERTICAL CONTACT TOASTER

P/N 1010840 Rev. M 07/14

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

HI

USE

Figure 7. “HI” Fault Message

“HI” will flash if platen

temperature exceeds 620°F

(327°C) or if platen thermocou-

ple is disconnected or “open”.

“HI” and “USE” will flash if

auxiliary heaters temperature

exceeds 440°F (227°C) or if

the Auxiliary Thermocouple

is disconnected or “open.”

Figure 8. “CHEC” Fault Message

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

CHEC

“CHEC” will flash when

control compartment

ambient temperature is

excessive: 140°F (60°C) to

180°F (82°C). All heaters will

shut off.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

PO

“PO” will flash if

incoming power drops below

190 Volts. Toaster shuts

down.

Figure 9. “PO” and “PH” Fault Messages

Fault messages

• If the Platen Thermocouple is disconnected or

“open”, the display will flash “HI.” The Platen

Thermocouple must be reattached or replaced.

• If the Platen Heater temperature exceeds 620°F

(327°C) the display will flash “HI” and the heating

circuit will turn off (Figure 7). After the toaster has

cooled down, the unit must be turned off, then back

on to restart. If this condition repeats, contact your

Authorized Service Agency.

• If the Auxiliary Heating temperature exceeds 420°F

(215°C) the display will alternately flash “HI” and

“USE” (Figure 7). After the toaster has cooled

down, the unit must be turned off, then back on

to restart. If this condition repeats, contact your

Authorized Service Agency.

• The temperature controller has an ambient

temperature sensor that will disable the heating

circuits if the control compartment ambient

temperature becomes excessive: 140°F (60°C)

to 180°F (82°C).

When this occurs, the temperature display will flash

“CHEC” (Figure 8). To restart the unit, ambient must

drop to 140°F (60°C) and the unit must be turned

off, then back on. If this condition repeats, contact

your Authorized Service Agency.

• If incoming power drops below 175 Volts, the heat-

ing circuits are disabled and the display will read

“PO” (Figure 9). To reset, the voltage must be over

190 Volts, then the unit must be turned off and back

on. If this condition repeats, contact your Authorized

Service Agency.

• The “PH” fault message (Figure 9) is displayed if

the Conveyor Interlock Safety Switch (Figure 1)

is not properly engaged . When a PH fault exists,

reposition the Heat Shield so that it fully engages

the Conveyor Safety Interlock Switch. The unit

should return to normal operation when the Heat

Shield is positioned correctly.

If the “PH” Fault does not clear, contact your

Authorized Service Agency for service.

OPERATION (continued)

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

ph

“PH” will flash when the

Conveyor Safety Interlock

Switch is not properly

engaged.