Vertical contact toaster, Troubleshooting – A.J. Antunes & Co VCT-2000 9210410 User Manual

Page 16

Advertising
background image

VERTICAL CONTACT TOASTER

16

P/N 1010840 Rev. M 07/14

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-

ment should be performed by qualified service personnel. The unit should be unplugged when servicing,

except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will

be exposed.

Problem

Possible Cause

Corrective Action

Control Display Flash-

es “LO” continuously

Buns not toasting

properly.

Platen temperature is below 440ºF

(226ºC).

Allow the unit to warm up for 30 minutes and then

recheck. If the Control Display still reads “LO,” con-

tact your maintenance person or Authorized Service

Agency for service.

Control display flash-

es “LO” continuously.

Buns burn.

Failed Platen Thermocouple.

Contact your maintenance person or Authorized

Service Agency for service.

Failed Control Board.

Temperature display

flashes “PH”.

The Heat Shield is not fully engag-

ing the Conveyor Safety Interlock

Switch.

Reposition the Heat Shield so that it fully engages

the Conveyor Safety Interlock Switch.

Loose wiring between the phase

control and A/C isolator boards.

Contact your maintenance person or Authorized

Service Agency.

Control Display

flashes “PO” continu-

ously.

The power to the unit is below 190

volts.

Turn the Rocker Switch off and then back on. If the

display still shows “PO,” check the power cord, plug,

and outlet for damage.

Reset the Circuit Breakers.

Contact your maintenance person, Authorized

Service Agency, or electrician for service.

Failed Control Board.
Failed Transformer.

Control flashes

“CHEC” continuously.

Control Compartment temperature is

above 140ºF.

Verify side vents on toaster are unblocked and not

near other heating appliances. If problem still per-

sists, contact your maintenance person or Autho-

rized Service Agency for service.

Failed Cooling Fan.
Failed Control Board.

Control Display

flashes “HI” continu-

ously.

Buns burn.

Failed Platen Solid State relay.

Contact your maintenance person or Authorized

Service Agency for service.

Failed Control Board.
Failed Platen Thermocouple.

Control Display flash-

es “HI” continuously.

Buns not toasting

properly.

Loose Platen Thermocouple connec-

tion on Control Board or the Platen

Thermocouple is open.

Re-secure the Platen Thermocouple connection to

the Control Board. If the Control Display still reads

“HI,” check the Thermocouple for continuity. Con-

tact your maintenance person or Authorized Service

Agency for service.

Failed Control Board.

Control Display

flashes “HI” & “LO” at

cold start up, then “HI”

& “USE” after 20 - 30

minutes.

Loose Auxiliary Thermocouple con-

nection on Control Board or Thermo-

couple is “open.”

Re -secure the Auxiliary Thermocouple connection to

the Control Board. If the Control Display still reads

“HI” & “LO” or “HI” & “USE,” check Thermocouple

for continuity. Contact your maintenance person or

Authorized Service Agency for service.